Suddenly, your home air conditioner stops cooling. One possible culprit is a malfunctioning blower. Join Mytour Supermarket in unraveling the reasons and remedies for the issue of a non-functioning air conditioner blower through this insightful article.
Reasons and solutions for non-operational air conditioner blowers
1. Signs indicating the air conditioner blower not running
When the air conditioner blower is not functioning, it prevents the gas from flowing through the copper pipes, causing blockages. Consequently, the air conditioner cannot operate efficiently for cooling.
If the air conditioner shows the following signs, it indicates that the blower may not be running:
+ The air conditioner unit becomes hotter than usual after starting.
+ The compressor operates continuously but fails to provide cooling.
+ The air conditioner blower shuts off intermittently.
+ The air conditioner produces loud noise with unstable temperature.

The air conditioner blower is malfunctioning.
2. Causes of Air Conditioner Blower Failure
Here are common reasons for the air conditioner blower not running.
+ The compressor operates continuously, overloading without rest.
+ The air conditioner blower is jammed.
+ Failure to perform regular machine cleaning and maintenance allows dust to accumulate, affecting the internal motors.
+ Unstable power supply to the air conditioner results in erratic operation, leading to blower burnout and damage.
+ Placing the air conditioner in an excessively hot location with direct sunlight leads to overload due to poor heat exchange.
+ Refrigerant circulation issues caused by a compromised heat exchanger or compressed pipes.

Regular maintenance and cleaning are necessary to prevent air conditioner blower failure.
3. Fixing the Issue of Non-Running Air Conditioner Blower
After detecting a malfunctioning air conditioner blower, regardless of the cause, the best course of action is to replace the blower to ensure the longevity of the unit.
To safely perform the blower replacement, follow these steps:
Step 1: Disconnect all power sources and proceed to remove the air conditioner blower.
Step 2: Weigh the cable according to the cooling capacity of the air conditioner. When the blowers ensure the correct technical specifications, proceed to install them into the unit.
Step 3: Perform hygiene on the internal components of the air conditioner.
Step 4: Install the remaining pipes and check for leaks by creating pressure inside. Then, use a gauge to check for any gaps.
Step 5: Charge the appropriate gas for the newly installed compressor.
Note: Before gas charging, it must be vacuumed thoroughly. The gas to be charged must be of the correct type and meet the specifications provided by the manufacturer.

Procedure for Installing a New Air Conditioner Blower
The process of replacing a new air conditioner blower can be quite complex. To ensure safety and the quality of the air conditioner, it is recommended to contact reputable maintenance centers for quick and effective assistance.
We hope that this article helps you identify the reasons for the air conditioner blower not running and provides the most effective solutions.