Having your Toshiba 9000 BTU 1-way Inverter RAS-H10X2KCVG-V air conditioner leaking water is not a common but not an uncommon issue either. There are several reasons leading to this situation. Let's explore and find the answer together on Mytour.
The consequences of water leakage in Toshiba 1hp inverter RAS-H10X2KCVG-V air conditioner

Toshiba air conditioners in general, or specifically the 1hp inverter RAS-H10X2KCVG-V model leaking water can cause rooms to be damp, causing discomfort and even providing conditions for mold growth if prolonged.
In addition, water leakage in the air conditioner's evaporator can lead to electrical short circuits, posing a danger to family members. Of course, when Toshiba air conditioners leak water, they also often have reduced cooling capacity, so you need to address this issue immediately when it occurs.
Causes of water leakage in Toshiba RAS-H10X2KCVG-V inverter air conditioner
For a Toshiba air conditioner leaking water, there could be various reasons. Basically, it could be due to the following:
Incorrect air conditioner installation

If your newly purchased Toshiba RAS-H10X2KCVG-V air conditioner suddenly leaks water, it could be because the installer lacks experience and has incorrectly installed the air conditioner. Typically, they may install the drainage pipe without slope or make it too long without ventilation holes, causing the Toshiba air conditioner to leak water.
Damage during transportation or installation
Another reason is damage during transportation or installation, causing the Toshiba 9000 BTU 1-way Inverter RAS-H10X2KCVG-V air conditioner to crack. The air conditioner's water tray is where water accumulates and then drains through the drainage pipe. If the water tray is cracked or broken, water will leak out.
Dirt accumulation on the air conditioner evaporator due to lack of cleaning over time
In cases where the evaporator of the air conditioner collects dust over time, the process of releasing cold air outside will not be properly accumulated, resulting in water droplets following the machine's body outside. Therefore, users should clean the air conditioner regularly every 3-4 months.

Air conditioner lacking or running out of gas
The Toshiba RAS-H10X2KCVG-V 1hp air conditioner leaking water could be due to gas shortage or depletion. Gas is essential for the air conditioner to operate normally.
If the gas supply process is interrupted, the inverter air conditioner will frost up, leading to water leakage outside.
Water leakage due to malfunctioning of the evaporator fan
For the air cooling process, if the air distribution process throughout the room relies on the fan of the evaporator. If the fan blades are damaged or broken, air cannot be distributed properly, inevitably leading to water leakage.
Leaking drain pipe
Similar to the case of a broken water tray, if the process of wall-mounting or drilling the drainage pipe of the air conditioner is flawed, it will cause the air conditioner to malfunction and also be the cause of water leakage.
Ways to troubleshoot Toshiba air conditioner water leakage
There are various reasons why the Toshiba inverter 1hp RAS-H10X2KCVG-V air conditioner leaks water. Depending on the cause, you need different troubleshooting methods for the most effective results. However, all of them require skilled technicians to fix.
According to us, when encountering the situation of Toshiba 9000 BTU 1-way Inverter RAS-H10X2KCVG-V air conditioner leaking water, you should call the warranty center or skilled repair technicians to ensure the air conditioner operates smoothly.
Conclusion
With the information provided above, we hope to help you understand the causes and solutions for water leakage in the Toshiba RAS-H10X2KCVG-V 10000 BTU air conditioner. If your air conditioner is still under warranty, you should contact the manufacturer for warranty service. If the warranty has expired, you should seek out the most reputable and professional repair facilities.